Accessible Routes from site arrival points to accessible entrances are required.
1.1 There are no accessible routes from site arrival points (parking, passenger loading zones, public sidewalks and transit stops) violating Section 206.2.1 of the 2010 ADA Standards.
Notes Photos Actions
   

Accessible Parking - Spaces should be identified by size, access aisles and signage.
1.2 Parking for the public does not provide an adequate number of accessible spaces, violating Section 208.2 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   
1.2 Parking for the public does not provide an adequate number of accessible spaces, violating Section 208.2 of the 2010 ADA Standards for Accessible Design.

1.3 There is not an adequate number of van accessible spaces, violating Section 208.2.4 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.4 Accessible spaces are not at least 8 feet wide with access aisles at least 5 feet wide, violating Section 505 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.5 Van accessible spaces are not at least 11 feet wide with access aisles 5 feet wide or 8 feet wide with access aisles at least 8 feet wide, violating Section 502.2 of the 2010 ADA Standards.
Notes Photos Actions
   

1.6 There is not at least 98 inches of vertical clearance provided for the van accessible space, violating Section 502.5 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.7 Access aisles not marked to discourage parking in them violating 2010 ADAS Section 502.3.
Notes Photos Actions
   

1.8 Accessible parking spaces and access aisles contain slopes steeper than 1:48, violating Section 502.4 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.9 Access aisles fail to adjoin accessible routes, violating Section 502.3 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.10 Accessible spaces lack signs at least 60 inches above ground that includes the ISA violating Section 502.6 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.11 Van accessible spaces lack proper signage violating Section 502.6 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.12 Accessible spaces are not located on the nearest most direct accessible route to accessible entrance(s), in violation of Section 208.3.1 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

Exterior Accessible Routes
1.13 Accessible routes are not stable, firm and slip-resistant in violation of Section 302.1 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.14 The route is not at least 36 inches wide, violating Section 403.5.1 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.15 Accessible routes > 200’ long and < 60” wide lack passing spaces < 60” x 60” required in Section 403.5.3 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.16 Openings along the accessible route violate 302.3 of the 2010 ADA Standards.
Notes Photos Actions
   

1.17 Running slopes > 1:20 on exterior accessible routes violate 2010 ADAS Section 403.3.
Notes Photos Actions
   

1.18 Cross slopes > 1:48 on exterior accessible routes violate 2010 ADAS Section 403.3.
Notes Photos Actions
   

Curb Ramps
1.19 There is no curb ramp where the accessible route crosses a curb, violating Section 402.2 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.20 The running slope of the curb ramp is steeper than 1:12, in violation of Sections 406.1 and 405.2 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.21 The cross slope of the curb ramp is steeper than 1:48, in violation of Sections 406.1 and 405.3 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.22 The curb ramp is not at least 36 inches wide, in violation of Sections 406.1 and 405.5 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.23 The curb ramp top landing violates 2010 ADA Standards Section 406.4.
Notes Photos Actions
   

1.24 Curb ramp flares fail to comply with Section 406 of the 2010 ADA Design Standards.
Notes Photos Actions
   

Ramps - any portion of an exterior accessible route steeper than 1:20 is treated as a ramp.
1.25 Ramp is not at least 36 inches wide, violating Section 405.5 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.26 The ramp surface is not stable, firm and slip resistant violating Section 405.4 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.27 Ramps contain running slopes greater than 1:12 violating 2010 ADAS Section 405.2.
Notes Photos Actions
   

1.28 Ramp landings fail to comply with 405.7 of the 2010 ADA Standards.
Notes Photos Actions
   

1.29 Level landings at least 60 x 60 inches are not provided where ramp runs change direction, violating Section 405.7.4 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.30 Ramp has a rise higher than 6 inches and does not provide handrails on both sides, in violation of Section 405.8 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.31 Handrail gripping surfaces fail to comply with Section 505.4 of the 2010 ADA Standards.
Notes Photos Actions
   

1.32 Handrail gripping surfaces fail to comply with Section 505 of the 2010 ADA Standards.
Notes Photos Actions
   

1.33 Circular handrail gripping surfaces fail to comply with Section 505.7.1 of the 2010 ADAS.
Notes Photos Actions
   

1.34 Non-circular handrail gripping surfaces fail to comply with 2010 ADAS Section 505.7.2.
Notes Photos Actions
   

1.35 Handrail extensions violate 2010 ADA Standards for Accessible Design Section 505.10.1.
Notes Photos Actions
   

1.36 Ramp lacks edge protection violating Section 405.9 of the 2010 ADA Standards.
Notes Photos Actions
   

Entrance Access
1.37 Main entrance is inaccessible violating Section 206.4 of the 2010 ADA Standards.
Notes Photos Actions
   

1.38 Entrances fail to comply with Section 206.4 of the 2010 ADA Standards.
Notes Photos Actions
   

1.39 Inaccessible entrances lack signs indicating the location of the nearest accessible entrance, violating Section 216.6 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.40 Accessible entrance lacks signage required by Section 216.6 of the 2010 ADA Standards.
Notes Photos Actions
   

1.41 Clear opening width of the accessible entrance door fails to comply with Section 404.2.3 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.42 Maneuvering clearance violates Section 404.2.4 of the 2010 ADA Standards.
Notes Photos Actions
   

1.43 Door threshold fails to comply with 2010 ADA Standards Sections 404.2.5 and 303.2.


Notes Photos Actions
   

1.44 Door hardware violates Section 404.2.7 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.45 Operable parts of door hardware are less than 34” or more than 48” above the ground surface, in violation of Section 404.2.7 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.46 Door closer fails to comply with Section 404.2.8 of the 2010 ADA Standards.
Notes Photos Actions
   

1.47 Doors in a series fail to comply with Section 404.2.6 of the 2010 ADA Standards.


Notes Photos Actions
   

1.48 Carpets or mats provided are greater than ½ inches thick, in violation of Section 302.2 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   

1.49 Edges of carpets and mats are not securely attached, violating Section 302.2 of the 2010 ADA Standards for Accessible Design.
Notes Photos Actions
   